ESD Anti-StaticControl the Charge. Protect the Product.
Electrostatic discharge can destroy sensitive electronics in milliseconds. ESD flooring provides a controlled path to ground, keeping static charges below damaging thresholds. Critical for electronics manufacturing, data centers, and any environment with sensitive components.
Precision Static Control
Controlled Resistance
Resistance values maintained within ±1 decade of specification. Consistent performance across the entire floor area.
Grounding Network
Copper strip grid embedded in primer coat, connected to facility ground. Multiple ground points for redundancy.
Body Voltage Control
Limits human body voltage generation to below 100V — well within safe thresholds for sensitive electronics.
Cleanroom Compatible
Low-particle emission, seamless surface meets ISO 14644 cleanroom standards. No outgassing after cure.
Chemical Resistance
Resists solvents, IPA, flux cleaners, and chemicals commonly used in electronics manufacturing.
Long-Term Stability
Resistance values remain stable over 15+ years. No degradation from cleaning, foot traffic, or environmental changes.
Everything in one
transparent package.
Final cost depends on area, condition, and system requirements. You'll get an exact quote after our free inspection.
6 steps. Zero shortcuts.
Here's exactly what we do.
Questions about
esd anti-static.
Conductive floors (<10⁶ Ω) rapidly drain charge — used where sparks could cause explosions. Dissipative floors (10⁶-10⁹ Ω) drain charge more slowly and safely — used for electronics where controlled discharge is needed.
A copper strip grid is installed beneath the coating, connected to the building's earthing system. Multiple ground points provide redundancy. We verify continuity at every junction.
We test resistance point-to-point, point-to-ground, and body voltage generation using calibrated meters per ANSI/ESD S20.20. Full test results with floor maps are provided.
Visually, ESD floors look nearly identical to standard epoxy. Slight color variations may exist due to conductive fillers. We offer multiple colors to match facility aesthetics.
Yes, if the existing concrete is sound. Old coatings are removed, and the full ESD system (copper grid, conductive primer, ESD topcoat) is installed. This is common in facility upgrades.
Have a floor to spec?
Let's engineer it.
Send your drawings or describe your space. We'll inspect the slab, spec the right system, and send a fixed-price quote with line-item breakdown — within 48 hours. No obligations, no chase calls.